SAE J2064 Explained: A/C Hose Types A-G, Permeation Limits, and What Most Suppliers Get Wrong

2026-10-10 · Industry Insights · Hebei Yuyang Auto Parts Co., Ltd.

Search “SAE J2064 hose types” and you will find three articles giving three different answers. One says the standard defines four types rated by pressure — 350, 500 and 550 psi. Another says Type C is only for the low-pressure suction side. A third quotes a permeation limit of 0.16 kg/m²/year, a number that does not appear anywhere in the standard.

This matters more than an academic argument. When a hose fails on a fleet vehicle, the document that gets pointed at is J2064. If you are buying hose by the meter or specifying assemblies for a customer, you need to know what the standard actually requires — and which of the numbers you are being quoted are real.

What follows is taken from the standard text and from how the testing is actually performed, then translated into the questions you should be asking a supplier.

1. First, the mix-up that causes most of the confusion

SAE publishes two standards for mobile air conditioning hose, and they cover different things:

  • SAE J3062 — “Automotive Refrigerant Air-Conditioning Hose Requirements”. This is the bulk hose standard. Hose sizes, structure types, moisture ingression classes and identification markings live here.
  • SAE J2064 — “Coupled Automotive Refrigerant Air-Conditioning Hose Assemblies”. This is the assembly standard: hose plus factory or field-coupled fittings and crimping tools.

Here is the part almost every article gets wrong: the seven hose structure types — A through G — are defined in J3062 and referenced by J2064. J2064 does not invent its own type system, and it does not sort hose into pressure tiers. It says, in effect, “the hose in this assembly must already have met J3062”.

Practical consequence: if you buy bulk hose by the meter, the structure type you are buying is a J3062 classification. If you buy a crimped assembly, J2064 adds three tests that do not exist on the bulk hose side — coupling integrity, bursting strength and proof test. A supplier who quotes you “J2064 hose” without being able to say which is which has probably not read either document.

2. The seven structure types

Type letters describe how the hose is built. Nothing more.

TypeStructure (as defined in SAE J3062 / referenced by J2064)ReinforcementBarrier layer
AElastomeric, textile reinforcedTextile yarn / cordNone
BElastomeric, wire reinforcedSteel wireNone
CBarrier, textile reinforcedTextile yarn / cordThermoplastic barrier between elastomer plies
DThermoplastic, textile reinforced, elastomeric coverTextile yarn / cordThermoplastic tube
EVeneer, textile reinforcedTextile yarn / cordThermoplastic liner veneered to the inner tube
FVeneer, barrier, thermoplastic linerTextile yarn / cordThermoplastic liner + barrier layer
GThermoplastic, textile reinforced, thermoplastic coverTextile yarn / cordThermoplastic tube and cover

A "u" suffix (Cu, Du, Eu, Fu, Gu) designates the ultra-low permeation limit.

Two things to take from this table:

  • Types A and B have no thermoplastic barrier. They are all-elastomer constructions. They still have to pass a permeation test — the limit is simply far more generous.
  • Types C through G all contain a thermoplastic layer. Whether it sits between plies (C, F), is veneered to the inner tube (E, F), or is the tube (D, G) is the difference between the letters.

3. Permeation limits: the numbers that actually exist

Hose typeR-134aR-1234yfR-152a
A, B15 kg/m²/year18 kg/m²/year18 kg/m²/year
C, D, E, F, G5 kg/m²/year5 kg/m²/year5 kg/m²/year
Cu, Du, Eu, Fu, Gu1.5 kg/m²/year1.5 kg/m²/year1.5 kg/m²/year

Permeation limits, SAE J2064 Table 2. These are maximum permitted loss rates, not typical values.

Read that table carefully, because it is the single most useful thing in the standard:

  • 15 vs 5. On R134a, a barrier construction is allowed to lose one third of what a non-barrier construction may lose. That is the entire business case for barrier hose, and it applies to R134a — not just to R1234yf.
  • R1234yf is harder on A/B hose. The limit for A/B rises to 18 on R1234yf and R152a, while barrier types stay at 5. The gap widens from 3x to 3.6x.
  • 1.5 is the “u” class. Ultra-low permeation. If a supplier claims “ultra-low”, the number they should be showing you is at or below 1.5 kg/m²/year, measured to this method.
  • These are ceilings, not averages. A compliant hose typically measures well under the limit — which is exactly why a good supplier quotes a measured value, not the limit.

4. Converting the units (so you can compare two quotes)

The standard reports permeation in kg per square metre of internal surface area per year. Suppliers in different markets report g/day, g/m/year, or oz/year. Here are the official conversion factors:

Nominal sizeMean I.D. (mm)Factor: g/day → kg/m²/yearFactor: g/day → lb/ft²/year
8 (5/16")8.113.4142.748
10 (13/32")10.610.2512.100
13 (1/2")13.08.3581.713
16 (5/8")16.16.7491.383
19 (3/4")19.45.6011.148

Conversion factors, SAE J2064 Table 1. For sizes not listed: factor = 108.66 / D (D = inside diameter in mm) for kg/m²/year, or 0.877 / D (D in inches) for lb/ft²/year.

And here is the translation most buyers actually want — what those limits mean in grams of refrigerant lost per metre of hose per year:

Nominal I.D.Inner surface per metre (m²/m)Type A/B limit (15)Type C-G limit (5)Ultra-low "u" limit (1.5)
8 mm0.0254382 g127 g38 g
10 mm0.0333500 g166 g50 g
13 mm0.0408613 g204 g61 g
16 mm0.0506759 g253 g76 g
19 mm0.0610914 g305 g91 g

Grams of refrigerant per metre of hose per year, converted from the kg/m²/year limits above. Figures correspond to the 80 °C accelerated test condition, not to real-world annual loss — see the note below.

Important caveat: these figures correspond to the accelerated test condition (see below), which runs at 80 °C. Real-world loss on a vehicle at ambient temperature is substantially lower. Do not put 127 g/m/year on a quotation and present it as a field figure — use it to compare two hoses against each other, which is what it is good for.

5. How the permeation test is actually run

This is the detail that separates a credible data sheet from a hopeful one. The test procedure is:

  1. Cut a specified length of hose, or build an assembly with production-intent fittings.
  2. Charge it with refrigerant.
  3. Place it in a constant-temperature oven at 80 °C ± 2 °C.
  4. Hold it there for 25 days.
  5. Measure the refrigerant loss and convert using the factors above.

Two implications you can use immediately:

  • A permeation number without a temperature is meaningless. If a supplier quotes “1.6 kg/m²/year” but cannot tell you the test temperature or the refrigerant, you are looking at a number copied from someone else’s catalogue.
  • Check the units. It is common to see permeability printed as “kg/m³/year” on Chinese supplier tables. That is a typo for m² — but it tells you the sheet was not written by the person who ran the test.

6. High side vs low side: which type goes where

The standard’s own guidance is straightforward:

  • High side (compressor to condenser, and liquid lines): Types C, D, E, F, G — every one of them includes a thermoplastic layer specifically to minimise permeation.
  • Low side (evaporator outlet back to compressor): normally Type A or B. These have no thermoplastic barrier, but must still meet their own permeation limit.

So the popular claim that “Type C is a suction-side-only hose” is backwards. It is the non-barrier A/B constructions that belong on the low side.

7. Four claims you should stop believing

What you read onlineWhat the standard actually saysWhy it costs you money
"J2064 defines four hose types rated by pressure: 350 / 500 / 550 psi"J2064 does not rate hose by psi. It defines seven structure types (A–G) based on tube material, reinforcement and barrier construction.You end up comparing quotes on a number the standard never issued.
"Type C is for the low-pressure suction side only"Types C, D, E, F and G are the constructions intended for the high side; Types A and B are the ones normally used on the low side.Fitting an A/B hose on a discharge line is a real burst risk, not a spec quibble.
"Permeation limit is 0.16 kg/m²/year"The published limits are 15 / 5 / 1.5 kg/m²/year. Numbers like 0.16 are a single manufacturer's measured result, presented as if it were the limit.You cannot compare your supplier against a competitor's marketing number.
"Barrier hose is only needed for R1234yf"A barrier construction is required for R134a too — the limit is 5 kg/m²/year for C–G versus 15 for A/B. The gap is roughly 3x.A charge that disappears every season is a warranty claim, not a mystery.

8. What the rest of the standard tests — and which three only apply to assemblies

TestSAE J3062 (bulk hose)SAE J2064 (coupled assembly)What it catches
Permeation✓✓Refrigerant escaping through the wall
Coupling integrity—✓Ferrule slipping or weeping at the crimp
Aging✓✓Hardening, cracking after heat exposure
Cold test✓✓Cracking at low temperature / bending
Vacuum flattening✓✓Collapsing under evacuation
Length change✓✓Swelling that pulls on the crimp
Bursting strength—✓Safety margin over working pressure
Proof test—✓Leakage under a sustained hold
Extraction✓✓Contaminants leaching into the refrigerant
Ozone✓✓Surface cracking from ozone attack
Cleanliness✓✓Particles that block expansion valves
Moisture ingression✓✓Water entering through the wall

If you crimp in-house and sell the finished assembly, you own the three assembly tests. That is worth knowing before you quote a warranty: coupling integrity and proof testing are where field-crimped assemblies most often fail, and neither is covered by a bulk hose certificate.

9. Where our series sit

Our seriesConstructionClosest J2064 structureRefrigerantsTemperature
EA44-layer thin wallC / E class construction with PA barrierR134a, R1234yf-40 °C to +125 °C (max. +150 °C)
CA55-layer thin wallC / E class, additional elastomer plyR134a, R1234yf-40 °C to +125 °C
CA95-layer thick wallC / E class, heavy wall for abrasionR134a, R1234yf-40 °C to +125 °C
EA48Refrigerated transport hoseA / B class all-elastomer constructionR404a, R410a-40 °C to +140 °C

Structure class is stated as the closest equivalent. We publish measured inspection values rather than a certification mark we cannot substantiate.

Our measured inspection results, from production batch test reports:

  • Burst: 35 MPa measured — more than 2.5x the 13.7 MPa minimum burst figure required for the size tested, and roughly 10x the 3.5 MPa working pressure
  • Proof test: 7.0 MPa hold, no leakage or abnormality
  • Length change at 3.0 MPa: measured 0%, against a +2% / −4% allowance. A hose that grows under pressure pulls on the ferrule until it weeps.
  • Wall eccentricity: 0.15–0.33 mm measured against a 0.4 mm limit. Eccentricity is what makes a crimp seal on one side and leak on the other.
  • EA48 permeation: tested with R404a / R410a at +80 °C, max. 9.7 kg/m²/year — inside the 15 kg/m²/year limit that applies to an all-elastomer construction
  • EA48 heat aging: +140 °C × 200 h

Test records ship with the order. If a number matters to your customer, ask for the record rather than the catalogue.

10. A spec checklist you can send to any supplier

  1. Type letter — and whether they mean the J3062 structure or are using the letter loosely.
  2. Refrigerant the permeation figure was measured with. R134a, R1234yf and R404a are not interchangeable.
  3. Measured permeation value with the test temperature, not the limit from the standard.
  4. Burst and proof pressure on the actual size you are buying.
  5. Length change at working pressure.
  6. Wall eccentricity — the quiet cause of crimp leaks.
  7. Minimum bend radius for the size.
  8. Date code. Bulk A/C hose has a shelf life; rubber older than about three years loses flexibility and crimps poorly.

Related reading and products

Hose is supplied by the meter from stock, MOQ 100 meters per size, shipping in 3–7 days for stocked sizes. Send us the refrigerant, the I.D., the operating temperature and whether the run is suction or discharge, and we will tell you which structure fits.

Frequently asked questions

What is the difference between SAE J3062 and SAE J2064?
SAE J3062 covers bulk hose — sizes, structure types, moisture ingression classes and identification. SAE J2064 covers coupled assemblies, meaning hose with factory or field-crimped fittings. The seven structure types (A through G) are defined in J3062 and referenced by J2064. J2064 adds three assembly-only tests: coupling integrity, bursting strength and proof test.
How many hose types does SAE J2064 define?
Seven — Type A through Type G — and they describe construction, not pressure rating. A is elastomeric with textile reinforcement, B is elastomeric with wire reinforcement, C is barrier with textile reinforcement, D and G are thermoplastic, E is veneer with textile reinforcement, and F is veneer with a barrier and thermoplastic liner. A 'u' suffix (Cu, Du, Eu, Fu, Gu) designates the ultra-low permeation limits.
What are the permeation limits in SAE J2064?
For R134a: 15 kg/m2/year for Types A and B, 5 kg/m2/year for Types C through G, and 1.5 kg/m2/year for the ultra-low 'u' class. For R1234yf and R152a the A/B limit is 18 kg/m2/year while barrier types stay at 5 and the u class stays at 1.5. These are maximum permitted loss rates measured at 80 C over 25 days.
Is Type C hose for the high side or the low side?
Types C, D, E, F and G are the constructions intended for the high side, because each contains a thermoplastic layer that limits permeation. Types A and B are normally used on the low side. The claim that Type C is suction-side only is incorrect.
How do I convert a permeation figure from g/day to kg/m2/year?
Multiply the grams per day figure by the factor for that hose size. SAE J2064 Table 1 gives 13.414 for 8 mm, 10.251 for 10 mm, 8.358 for 13 mm, 6.749 for 16 mm and 5.601 for 19 mm nominal. For any other size, the factor is 108.66 divided by the inside diameter in millimetres.
Do I need barrier hose for R134a, or only for R1234yf?
You need it for both. On R134a the limit is 5 kg/m2/year for barrier constructions versus 15 kg/m2/year for non-barrier A/B hose — a factor of three. On R1234yf the A/B limit rises to 18, so the gap widens further. A system that loses charge every season with no visible leak is the classic symptom of non-barrier hose on a modern refrigerant.
Does a bulk hose certificate cover a crimped assembly?
No. Coupling integrity, bursting strength and proof testing are assembly-level tests under SAE J2064 and are not covered by a bulk hose certificate. If you crimp in-house, you own those three tests and the warranty that goes with them.